The "Next Generation" The Next Generation of Automatic Material Distribution Systems
CART-MATIC
VFD DOOR CONTROL
Each COURION CART-MATIC VFD Door Controller is customized for your facility's unique operational procedures. COURION's VFD Controller provides the "smarts" to fully operate the doors, car gate, transfer unit, and other operations needed to insure proper performance of your COURION CART-MATIC Cart System.
PLC Based. COURION's CARTMATIC VFD Door Control is built around an industry proven programmable PLC. The PLC unit contains two communication ports which allows the control program to be easily updated to meet your ever changing needs. Superior VFD Motor Control. COURION's new VFD Door Controller utilizes two variable frequency drives to provide superior door and car gate motor control. Your doors and car gate will open and close smoothly every time. 100% Factory Tested. COURION's quality control guarantees quality and reliability. Every Courion Door Control is factory tested. CART-MATIC VFD CONTROL
www.couriondoors.com
3044 Lambdin Ave. St. Louis, Missouri 63115 (800) 533-5760 (314) 533-5700 (314) 533-5720 (fax) e-mail:
[email protected]
The "Next Generation" The Next Generation of Automatic Material Distribution Systems
VFD Controller Key #
Part #
Part Description
q
90-039006
DL205 Slot Base
w
90-038000
DL240 CPU
e
90-036000
DL16NA Input Card
r
90-036108
DL08TRS Relay Output
t
90-883000
Transformer (150VA/230/115v)
y
90-210200
VFD Unit
u
e-1223
Relay Socket
i
90-510010
Relay (120VAC)
o
90-520001
Contactor
a
90-525000
Adder Deck (4, N.C.) Typical Control measures 20" (wide) x 30" (tall) x 8" (deep).
DL240 CPU The DL240 CPU is a powerful CPU with multiple communication ports. The DL240 is preprogrammed by COURION for your specific needs and requirements. Field adjustments are limited to the four (4) Potentiometers on the face of the CPU.
Potentiometer CH1 - Timed Closed Delay CH2 - Close Warning Delay CH3 - Door Operation Timer CH4 - Transfer Unit Operation Timer
Minimum 15 sec. 5 sec. 15 sec. 15 sec.
Maximum 60 sec. 15 sec. 60 sec. 45 sec.
VFD Drive Unit When delivered, your COURION VFD Unit's parameters are preset to provide you with the optimal performance of your COURION CART-MATIC system. Depending on your specific installation, the following adjustments may be required.
Par P-03 P-04 P-20 P-21
Description Acceleration Deceleration Preset/Jog Speed 1 Preset/Jog Speed 2
Range 0 to 3.000s 0 to 3.000s 0 to 65Hz 0 to 65Hz
Default 0.5s 0.5s 35Hz 55Hz
CMVFD 2008